Files
uptimesebi/internal/web/percent.go
Sebastian UnterschützandClaude Opus 5.5 273a958d76 feat(web): switch charts between 1h, 3h, 12h, 24h and 7d with matching SLA
Bars use a resolution fitting the range and the latency line is placed
by time. The SLA is the share of time a monitor was not down, counted
from incidents and only since the monitor exists. Monitor pages list the
SLA from one hour to 90 days.

Closes #59

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_017GpWAskjmYtZpuQ5JwYTX3
2026-11-22 09:29:34 +01:00

16 lines
410 B
Go

package web
import (
"math"
"strconv"
)
// trimPercent cuts v to digits decimals instead of rounding, so 99.9996
// never reads as a perfect 100. The epsilon absorbs float noise such as
// 99.12 being stored as 99.1199999.
func trimPercent(v float64, digits int) string {
scale := math.Pow(10, float64(digits))
v = math.Floor(v*scale+1e-6) / scale
return strconv.FormatFloat(v, 'f', digits, 64) + "%"
}